Ex1s Series Master Unit |
|
|
Model |
I/O Number |
Inputs |
Outputs |
pdf |
|
Ex1s24MR |
24 |
16 |
Sink / Source
selectable |
8 |
Relay |
|
Ex1s24MT |
Transistor (NPN) |
Ex1s32MR |
32 |
16 |
16 |
Relay |
Ex1s32MT |
Transistor (NPN) |
|
Ex1n Series Master Unit |
|
|
Model |
I/O Number |
Inputs |
Outputs |
Dimensions |
|
Ex1n16MR |
16 |
8 |
Sink / Source
selectable |
8 |
Relay |
|
Ex1n14MT |
14 |
8 |
6 |
Transistor (NPN) |
Ex1n24MR |
24 |
16 |
8 |
Relay |
Ex1n24MT |
Transistor (NPN) |
Ex1n32MR |
32 |
16 |
16 |
Relay |
Ex1n32MT |
Transistor (NPN) |
|
Ex1n Series Master Unit – DC type |
|
|
Model |
I/O Number |
Inputs |
Outputs |
Dimensions |
|
Ex1n16MR-D |
16 |
8 |
Sink / Source
selectable |
8 |
Relay |
|
Ex1n16MT-D |
Transistor (NPN) |
|
Ex2n Series Master Unit |
|
|
Model |
I/O Number |
Inputs |
Outputs |
Dimensions |
|
Ex2n24MR |
24 |
16 |
Sink / Source
selectable |
8 |
Relay |
|
Ex2n24MT |
Transistor (NPN) |
Ex2n32MR |
32 |
16 |
16 |
Relay |
Ex2n32MT |
Transistor (NPN) |
|
Expansion I/O Unit |
|
|
Model |
I/O Number |
Inputs |
Outputs |
Dimensions |
|
Ex1s08EX |
8 |
8 |
Sink / Source
selectable |
0 |
---- |
B type |
Ex1s08ER |
8 |
4 |
4 |
Relay |
Ex1s08ET |
Transistor (NPN) |
A type |
Ex1s08EYR |
8 |
0 |
---- |
8 |
Relay |
Ex1s08EYT |
Transistor (NPN) |
Ex1n16EX |
16 |
16 |
Sink / Source
selectable |
0 |
---- |
Ex1n16ER |
16 |
8 |
8 |
Relay |
Ex1n16ET |
Transistor (NPN) |
Ex1n16EYR |
16 |
0 |
---- |
16 |
Relay |
Ex1n16EYT |
Transistor (NPN) |
Ex1n24ER |
24 |
16 |
Sink / Source
selectable |
8 |
Relay |
Ex1n24ET |
Transistor (NPN) |
Ex1n32ER |
32 |
16 |
16 |
Relay |
Ex1n32ET |
Transistor (NPN) |
|
Remote I/O Module |
|
|
Model |
I/O Number |
Inputs |
Outputs |
Dimensions |
|
EXRM0808R |
16 |
8 |
Sink / Source
selectable |
8 |
Relay |
B type |
EXRM0808T |
Transistor (NPN) |
|
Wire Expansion Module |
|
|
Model |
I/O Number |
Wire Length |
Dimensions |
|
Ex1nNEXT-50 |
0 |
50cm |
C type |
Ex1nNEXT-80 |
80cm |
|
Power Expansion Module |
|
|
Model |
Wire Length |
Dimensions |
|
ExPower-E |
Input : 100-240VAC 50/60Hz |
B type |
Output : DC24V
±15%
500mA |
|
Positioning Controller (Ex2n1PG) |
|
|
EX1n1PG |
|
|
Item |
Specifications |
Number of
control axes |
1 axis / block,
maximum expand to 8 blocks |
Operation speed |
10pps ~ 100Kpps |
Setting position
data range |
-2,147,483,648 ~
2,147,483,647 |
Pulse output
format |
PLS and DIR, CW
and CCW |
Number of I/O
points occupied |
NONE |
Power
supply |
For input
signals |
24VDC±10%
from the output voltage of PLC, Current
consumption : 40mA or less |
For internal
control |
5VDC, 60mA
supplied from PLC via extension cable |
For pulse output |
24VDC±10%,
current consumption : 40mA or less |
Applicable PLC |
Ex1n / Ex2n
series PLC |
Dimensions |
C type |
Weight (NW) |
186gw |
|
|
Positioning Controller (Ex1n1PG) |
|
|
EX2n1PG |
|
|
Item |
Specifications |
Number of
control axes |
1 axis / block,
maximum expand to 8 blocks |
Operation speed |
10pps ~ 100Kpps |
Setting position
data range |
-2,147,483,648 ~
2,147,483,647 |
Pulse output
format |
PLS and DIR, CW
and CCW |
Number of I/O
points occupied |
NONE |
Power
supply |
For input
signals |
24VDC±10%
from the output voltage of PLC, Current
consumption : 40mA or less |
For internal
control |
5VDC, 60mA
supplied from PLC via extension cable |
For pulse output |
24VDC±10%,
current consumption : 40mA or less |
Applicable PLC |
Ex1n / Ex2n
series PLC |
Dimensions |
C type |
Weight (NW) |
186gw |
|
|
Signal Conversion Module - (
Ex1nLTOC Line driver TO open Collector ) |
|
|
|
|
|
Item |
Specifications |
Input signal |
Line Driver Signal (PA, PA, PB,
PB, PZ, PZ) |
Output signal |
Open Collector Signal (A, B,
Z) |
Number of I/O points occupied |
None |
Power supply |
24VDC ±10%,
40mA or less |
Applicable PLC |
Ex1n / Ex2n series PLC |
Dimensions |
C type |
Weight |
140gw |
|
|
Signal Conversion Module - (
Ex1nLTOL Line driver TO open Collector ) |
|
|
|
|
|
Item |
Specifications |
Input signal |
Open Collector Signal (A, B,
Z) |
Output signal |
Open Collector Signal (A, B,
Z) |
Number of I/O points occupied |
None |
Power supply |
24VDC ±10%,
40mA or less |
Applicable PLC |
Ex1n / Ex2n series PLC |
Dimensions |
C type |
Weight |
140gw |
|
|
Ex1n2DA |
|
|
|
♦ Two channels for
voltage output (-10V ~ +10V DC) or current output (4 to
20mA DC)
♦ Voltage or Current
output can be specified for each channel
♦ 12bits + 1 sign bit
resolution |
|
Item |
Voltage output |
Current output |
Analog output range |
-10 to 10V DC |
4 to 20mA |
Resolution |
2.5mV [10-(-10)]V/8000 |
4 μA
[(20-4)mA/4000] |
Overall accuracy |
± 1%
(full scale –10 to +10V) |
± 1%
(full scale 4 to 20mA) |
Conversion speed |
2 scan-time / 1 channel |
Isolation |
Photo-coupler isolation between analog and
digital circuits
DC/DC converter isolates main unit power, no
isolation between analog channels |
Power supply |
5VDC, 50mA (digital circuit
power from main unit), 24VDC ±10%,
100mA (analog circuit) |
Number of occupied I/O points |
Occupy 16 output points |
Applicable PLC |
Ex1n, Ex2n series PLC |
Dimension |
C type |
Weight (NW) |
200gw |
|
|
Ex1n2AD |
|
|
|
♦ This module provide
2 channels of analog input conversion to digital value
♦ 11 bits + 1 sign
bit resolution, accuracy:
±1%
♦ Conversion speed :1
scan-time
♦ Number of occupied
I/O points : None
♦ Dimensions: C type
/ Weight (NW): 145gw |
|
Item |
Voltage output |
Current output |
Analog output range |
-10 to +10V DC |
4 to 20mA |
Resolution |
5.0mV (20V/4000) |
8 μA
(16mA/2000) |
Isolation |
Photo-coupler isolation between analog and
digital circuits
DC/DC converter isolates main unit power, no
isolation between analog channels |
Power supply |
5VDC, 50mA (digital circuit
power from main unit), 24VDC ±10%,
100mA (analog circuit) |
Applicable PLC |
Ex1s, Ex1n, Ex2n series |
|
|
Ex1n8AD |
|
|
|
♦ Eight channels for
voltage input (-10V to +10V DC) or current input (4 to
20mA DC)
♦ For each channel,
voltage or current input can be specified independently
♦ 11bits + 1 sign bit
resolution
♦ Power supply :
5VDC, 50mA (digital circuit power from main unit),
24VDC ±10%,
100mA (analog circuit)
♦ Dimensions : B type
/ Weight (NW) : 250gw |
|
Item |
Voltage output |
Current output |
Analog output range |
-10 to +10V DC (input
resistance 102K Ω) |
4 to 20mA DC (input resistance
500 Ω) |
Resolution |
5mV (20V/4000) |
8 μA
[(20-4)mA/4000] |
Overall accuracy |
± 1%
(full scale –10 to +10V) |
± 1%
(full scale 4 to 20mA) |
Conversion speed |
500 μs
x Number of used channel |
Isolation |
Photo-coupler isolation between analog and
digital circuits
DC/DC converter isolates main unit power, no
isolation between analog channels |
Number of occupied I/O points |
None |
Applicable PLC |
Ex1n, Ex2n series PLC |
|
|
Ex1s2LD |
|
|
|
♦ This module provide
2 channels of load cell module input
♦ 11 bits + 1 sign
bit resolution, accuracy:
±1%
full scale
♦ Conversion speed :
1CH / 2 scan-time
♦ Number of occupied
I/O points : None
♦ Dimensions: C type
/ Weight (NW): 138gw |
|
Item |
Type A |
Type B |
Rated output voltage |
10mV/10V |
20mV/10V |
Resolution |
11 bits |
11 bits |
Isolation |
Photo-coupler isolation between analog and
digital circuits
DC/DC converter isolates main unit power, no
isolation between analog channels |
Power supply |
5VDC, 50mA (digital circuit
power from main unit), 24VDC ±10%,
100mA (analog circuit) |
Applicable PLC |
Ex1n, Ex2n series PLC |
|
|
Ex1n2LD |
|
|
|
♦ This module provide
2 channels of load cell module input
♦ 11 bits + 1 sign
bit resolution, accuracy:
±1%
full scale
♦ Conversion speed :
1CH / 2 scan-time
♦ Number of occupied
I/O points : None
♦ Dimensions: C type
/ Weight (NW): 179gw |
|
Item |
Type A |
Type B |
Rated output voltage |
10mV/10V |
20mV/10V |
Resolution |
11 bits |
11 bits |
Isolation |
Photo-coupler isolation between analog and
digital circuits
DC/DC converter isolates main unit power, no
isolation between analog channels |
Power supply |
5VDC, 50mA (digital circuit
power from main unit), 24VDC ±10%,
100mA (analog circuit) |
Applicable PLC |
Ex1n, Ex2n series PLC |
|
|
Ex1s2PT |
|
|
|
♦ Platinum
temperature sensor (Pt100, 3 wire type) input, 2
channels
♦ 11 bits + 1 sign
bit resolution, accuracy:
±1%
full scale
♦ Conversion speed :
1CH / 2 scan-time
♦ Number of occupied
I/O points : None
♦ Dimensions: C type
/ Weight (NW): 144gw |
|
Item |
Centigrade ( °C) |
Fahrenheit ( °F) |
Analog input signal |
1mA sensor : 100 Ω
Pt100
(3850PPM /
°C) |
Resolution |
0.2 to 0.3 °C |
0.36 to 0.54 °F |
Isolation |
Photo-coupler isolation between analog and
digital circuits
DC/DC converter isolates main unit power, no
isolation between analog channels |
Power supply |
5VDC, 50mA (digital circuit
power from main unit), 24VDC ±10%,
100mA (analog circuit) |
Applicable PLC |
Ex1s, Ex1n, Ex2n series PLC |
|
|
Ex1n2PT |
|
|
|
♦ Platinum
temperature sensor (Pt100, 3 wire type) input, 2
channels
♦ 11 bits + 1 sign
bit resolution, accuracy:
±1%
full scale
♦ Conversion speed :
1CH / 2 scan-time
♦ Number of occupied
I/O points : None
♦ Dimensions: C type
/ Weight (NW): 180gw |
|
Item |
Centigrade ( °C) |
Fahrenheit ( °F) |
Analog input signal |
1mA sensor : 100 Ω
Pt100
(3850PPM /
°C) |
Resolution |
0.2 to 0.3 °C |
0.36 to 0.54 °F |
Isolation |
Photo-coupler isolation between analog and
digital circuits
DC/DC converter isolates main unit power, no
isolation between analog channels |
Power supply |
5VDC, 50mA (digital circuit
power from main unit), 24VDC ±10%,
100mA (analog circuit) |
Applicable PLC |
Ex1n, Ex2n series PLC |
|
|
Ex1s2TC |
|
|
|
♦ K or J type
thermocouple temperature sensor input
♦ 11 bits + 1 sign
bit resolution, accuracy:
±1%
full scale
♦ Conversion speed :
1CH / 2 scan-time
♦ Power supply :
5VDC, 40mA (digital circuit power from main unit),
24VDC ±10%,
100mA (analog circuit)
♦ Dimensions: C type
/ Weight (NW): 138gw |
|
Item |
Centigrade ( °C) |
Fahrenheit ( °F) |
Analog input signal |
K: -100 to 1200 °C,
J: -100 to 600°C |
K: -148 to 2192 °F,
J: -148 to 1112°F |
Resolution |
K: 0.4 °C,
J: 0.3°C |
K: 0.72 °F,
J: 0.54°F |
Isolation |
Photo-coupler isolation between analog and
digital circuits
DC/DC converter isolates main unit power, no
isolation between analog channels |
Number of occupied I/O points |
None |
Applicable PLC |
Ex1s, Ex1n, Ex2n series PLC |
|
|
Ex1n8TC |
|
|
|
Analog Input Block for Thermocouple Temperature Sensor
♦ K or J type
thermocouple temperature sensor input
♦ Centigrade (°C)
or Fahrenheit (°F)
measurement can be changed
♦ Eight input
channels
♦ Power supply :
5VDC, 50mA (digital circuit power from main unit),
24VDC ±10%,
100mA (analog circuit)
♦ Dimensions : B type
/ Weight (NW) : 250gw |
|
Item |
Centigrade ( °C) |
Fahrenheit ( °F) |
Analog input signal |
K: -100 to 1200 °C,
J: -100 to 600°C |
K: -148 to 2192 °F,
J: -148 to 1112°F |
Resolution |
K: 0.4 °C,
J: 0.3°C |
K: 0.72 °F,
J: 0.54°F |
Overall accuracy |
± 0.5%
(full scale 1°C) |
Conversion speed |
100ms x Number of used channel |
Isolation |
Photo-coupler isolation between analog and
digital circuits
DC/DC converter isolates main unit power, no
isolation between analog channels |
Number of occupied I/O points |
None |
Applicable PLC |
Ex1s, Ex1n, Ex2n series PLC |
|
|
Communication Module ( EX485LNK ) |
|
|
|
♦ Isolation :
Photo-coupler isolation
♦ CPU Link, 1 : N
network
♦ Applicable PLC :
Ex1n, Ex2n series PLC
♦ Dimensions: C type
♦ Weight (NW) : 191gw |
|
Item |
Specification |
Transmission standard |
RS422/485 |
Maximum transmission distance |
RS422/485 : 500m |
LED indicators |
SD, RD |
Communication method |
Half duplex |
Baud rate |
1200 / 2400 / 4800 / 9600 /
19200 / 38400 / 57600 / 115200 |
Power supply external |
24V DC
± 10%,
40mA |
Power supply internal |
5V DC, 80mA is supplied from
the main unit |
|
|
Communication Module ( EX232BD ) |
|
|
|
♦ Can communicate
with personal computer, bar code reader, operation panel
♦ Can use a dedicated
protocol to communicate with RS232C equipment
♦ Applicable PLC :
Ex1s, Ex1n, Ex2n series PLC
♦ Dimensions (W) x
(L) x (H) : 47mm x 89mm x 29mm
♦ Weight (NW) : 51gw |
|
Item |
Specification |
Transmission standard |
RS232C |
Maximum transmission distance |
15m |
LED indicators |
RXD, TXD |
Communication method |
Half duplex |
Isolation |
No isolation |
Power supply-Internal |
5V DC 20mA is supplied as the
power from the main unit |
|
|
Communication Module ( EX485BD ) |
|
|
|
♦ Can use a dedicated
protocol to communicate with multi RS422/485 equipments
♦ CPU Link, N : N
network
♦ Applicable PLC :
Ex1s, Ex1n, Ex2n series PLC
♦ Dimensions (W) x
(L) x (H) : 47mm x 89mm x 29mm
♦ Weight (NW) : 48gw |
|
Item |
Specification |
Transmission standard |
RS422/485 |
Maximum transmission distance |
50m |
LED indicators |
SD, RD |
Communication method |
Half duplex |
Isolation |
No isolation |
Power supply-Internal |
5V DC 30mA is supplied as the
power from the main unit |
|
|
Communication Module ( EX232ADP ) |
|
|
|
♦ Can communicate
with personal computer, bar code reader, operation panel
♦ Can use a dedicated
protocol to communicate with RS232C equipment
♦ Applicable PLC :
Ex1s, Ex1n, Ex2n series PLC
♦ Dimensions : C type
♦ Weight (NW) : 138gw |
|
Item |
Specification |
Transmission standard |
RS232C |
Maximum transmission distance |
50m |
LED indicators |
RXD, TXD |
Communication method |
Half duplex |
Isolation |
Photo-coupler isolation |
Power supply-external |
24V DC
±
10%, 50mA |
Power supply-Internal |
5V DC, 60mA is supplied from
the main unit |
|
|
Communication Module ( EX485ADP ) |
|
|
|
♦ Can use a dedicated
protocol to communicate with multi RS422/485 equipments
♦ CPU Link, N : N
network
♦ This is an
isolation type adapter for connect with inverter, servo
driver or long distance equipment
♦ Applicable PLC :
Ex1s, Ex1n, Ex2n series PLC
♦ Dimensions : C type
/ Weight (NW) : 140gw |
|
Item |
Specification |
Transmission standard |
RS422/485 |
Maximum transmission distance |
500m |
LED indicators |
SD, RD |
Communication method |
Half duplex |
Isolation |
Photo-coupler isolation |
Power supply-external |
24V DC
±
10%, 50mA |
Power supply-Internal |
5V DC, 60mA is supplied from
the main unit |
|
|
Linear / Circular Interpolation ( EX200MP ) |
|
|
|
♦
Digital input:16,Digital
output16,
♦
2 axis Linear and Circular
interpolation
♦
High Speed Counter
♦
AB phase:1×30 KHZ,1×5KHZ,
♦
Pulse Output 2×60KHZ,
♦
Port:RS232/485,
♦
Power:220VAC |
|
EX200MP
Wiring Diagram
|
|
|
|
|
Programming Software |
|
|
To Download Programming Software (
FXGPWIN )
Click Here |
|
Dimension |
|
|
|
|
|